SilverStone ST30SF User Manual

Page 3

Advertising
background image

2.2. SAFETY

CB: IEC 60950~1:2005(2nd Edition) and/or EN 60950~1:2006 +A11:2009

UL: UL 60951-1 , 2nd Edition, 2007-03-27

TUV: EN 60950-1:2006+All

3.2. INRUSH CURRENT

Maximum inrush current from power-on (with power on at any point on the AC sine)

and including, but not limited to, three line cycles, shall be limited to a level below

the surge rating of the input line cord, AC switch if present, bridge rectifier, fuse, and

EMI filter components. Repetitive ON/OFF cycling of the AC input voltage should not

damage the power supply or cause the input fuse to blow.

3. INPUT ELECTRICAL SPECIFICATIONS

3.1. AC INPUT

◆

Nominal voltages for test purposes are considered to be within ±1.0V of nominal.

Parameter

Mi n. Nom.

Max.

Unit

Vin (115VAC)

90

115

132

VAC rms

Vin (230VAC)

180

230

264

VAC rms

Vin Frequency

47

--

63

HZ

(1)

3.3. INPUT LINE CURRENT & POWER FACTOR (P.F.)

(At Full load)

AC input Input line current P.F.@ Full Load

P.F.@ Pin=75W

115V < 3.5 Amps – rms > 0.95 > 0.8

230V < 2.0 Amps – rms > 0.9 > 0.65