Sst-st50f-es230-manual-v1-p7-p8 – SilverStone ST50F-ES230 User Manual

Page 5

Advertising
background image

STRIDER ESSENTIAL SERIES

07

The MTBF of the power should be 50,000 hours min

10. MTBF

11.1 Input Voltage

Applying 220Vac for230Vac model.

11.2 Test Condition

Applying 75% loads for the power supply in 40 (+/-5) oC chamber for 4 hours.

11. Burn-In

* T1 : Turn on time ( 2 sec. Max.)
* T2 : Rise time ( ≦ 20mS Max.)
* T3 : Power good turn on delay time ( 100 < T3 < 500 mS )
* T4 : Switch on time (0.5 sec. Max.)
* T5 : Power good turn off delay time ( 1.0 mS Min.) PS-ON/OFF
* T6 : Power hold-on time ( 8 mS Min.)
* Power on-off cycle :
When the power supply is turned off for a minimum of 2.0 sec. and turn on again,
the power good signal will be asserted.

Time Diagram

Figure 1

AC

AC ON

AC OFF

POWER ON

POWER ON

+5Vs

PS-ON/OFF

+5V O/P

Power Good

T1

T4

T3

T2

T5

4.75V

4.75V

0.25V

T6

08

EPS 12V 8PIN connector

Yellow

Yellow

Yellow

Yellow

Signal

+12V

+12V

+12V

+12V

Pin

5

6

7

8

Pin

1

2

3

4

Signal

COM

COM

COM

COM

Black

Black

Black

Black

M/B 24PIN connector

The power supply with active power factor correction, and meet the EN61000-3-2
standards, The power factor is greater than 0.9 at 230V/50Hz, Max. load.

13.Power Factor

14.1 Physical Dimension

150 mm (W) × 86 mm (H) × 140mm (D)

14.2 Connectors

14. Mechanical Requirements

The product shall meet requirement for EN61000-3-2 & EN61000-3-3 :2003
standard of class D, test at 230Vac 50Hz.

12. Harmonics