ST70F-ES, ST60F-ES provides an efficiency of >80% when measured at full load
under 115V/60Hz and 230V/50Hz condition.

Maximum continuous total DC output power should not exceed 700W.

Maximum continuous combined load on +3.3VDC and +5VDC outputs shall
not exceed 150W.

Maximum combined load on 12V outputs shall not exceed 552W.

NOTE:
Noise test should be measured with 20 MHz bandwidth frequency oscilloscope.
The output terminal shall add a tantalum capacitor of 10uF in parallel with a
ceramic capacitor of 0.1uF.

Output
Voltage

1. +5V

0.2A

2. +12V

0.6A

4. -12V

5. +5Vs

6. +3.3V

0.0A

0.0A

0.1A

25A

46A

0.3A

2.5A

25A

--

--

--

--

--

±5%

±5%

±5%

±10%

±5%

70mV

120mV

150mV

70mV

70mV

Load
MIN

Peak Regulation

Range
MAX

Ripple
P-P Max

2.5 Efficiency

3.1 Normal Operation Output

3.1.1 ST70F-ES

3. OUTPUT CHARACTERISTICS

04

STRIDER ST1000

STRIDER ST1000-NV

Strider Essential Series

Maximum continuous total DC output power should not exceed 600W.

Maximum continuous combined load on +3.3VDC and +5VDC outputs shall
not exceed 150W.

Maximum combined load on 12V rails outputs shall not exceed 504W.

NOTE:
Noise test should be measured with 20 MHz bandwidth frequency oscilloscope.
The output terminal shall add a tantalum capacitor of 10uF in parallel with a
ceramic capacitor of 0.1uF.

The PSON# signal is required to remotely turn on/off the power supply, PSON#
is an active low signal that turns on the output power rails. When this is not pulled
low by the system, or left open, the outputs (except the +5VSB) turn off. This signal
is pulled to a standby voltage by a pull-up resistor internal to the power supply.

TTL level "H" 2.0 V - 5.25 V
"L" 0.0 V – 1.0 V

Output
Voltage

1. +5V

0.2A

2. +12V

0.6A

4. -12V

5. +5Vs

6. +3.3V

0.0A

0.0A

0.1A

25A

42A

0.3A

2.5A

25A

--

--

--

--

--

±5%

±5%

±5%

±10%

±5%

70mV

120mV

120mV

70mV

70mV

Load
MIN

Peak Regulation

Range
MAX

Ripple
P-P Max

3.1.2 ST60F-ES

3.2 Remote On/Off Controlled mode