Manual-st85f-gs(p158)-st75f-gs(p159)-p2, St85f-gs / st75f-gs – SilverStone ST85F-GS User Manual

Page 3

Advertising
background image

ST85F-GS / ST75F-GS

1.2 Inrush current regulation
The power supply must meet inrush requirements for any rated AC voltage, during
turn on at any phase of AC voltage, during a single cycle AC dropout condition,
during repetitive ON/OFF cycling of AC, and over the specified temperature range
(Top). The peak inrush current shall be less than the ratings of its critical components
(including input fuse, bulk rectifiers, and surge limiting device).

Note:
1.Voltage tolerance is requied at main connector and S-ATA connector(if used)
2.Output transient response tested DC voltage regulation range +5V,+12V,+3.3V ±5%

1.Maximum continuous total DC output power should not exceed 750W.
2.Maximum continuous combined load on +3.3VDC and +5VDC outputs shall not exceed
150W.
3.Maximum combined current for the +12V outputs shall be 62A(744W).
4.When +12V is load to 28A , -12V minimum load is 0.02A.
5.Peak total DC output power should not exceed 800W.
6.Peak power can be supported for 12 second.

2.1 DC voltage regulation

2.2 Load ranges
2.2.1: SST-ST75F-GS Load Range

2. DC OUTPUT

Parameter

+3.3V

+5V

+12V

-12V

+5VSB

Range

+/-3%

+/-3%

+/-3%

+/-10%

+/-5%

Min

+3.20

+4.85

+11.64

-13.20

+4.75

Nom.

+3.30

+5.00

+12.00

-12.00

+5.00

Max

+3.40

+5.15

+12.36

-10.80

+5.25

Unit

Volts

Volts

Volts

Volts

Volts

Parameter

+3.3V

+5V

+12V

-12V

+5VSB

Min(optional)

0.5

0.3

1.0

0

0.1

Nom.

-

-

-

-

-

Max

22

25

62

0.3

3.5

Unit

Amps

Amps

Amps

Amps

Amps

Advertising