Appendix a - cli ascii-based interface – Sonnet Technologies Web Management Tool User Manual

Page 64

Advertising
background image

viii

Appendix A - CLI ASCII-Based Interface

•

EmailNotify
Regulates Email notification.

Default: disabled.
set EmailNotify [enabled | disabled]
get EmailNotify

•

EmailNotifyAddress
Configures notification addresses. Index is a number between
1 and 5. Full Email address is a fully qualified Internet Email
address, not more than 128 characters long. Emails are sent
based on the warning level you set to trigger an Email alert.

Warning levels
None: no Emails
Critical: only critical severity events
Warning: warnings and critical events
Informational: information
All: all warnings, critical events and informational messages

set EmailNotifyAddress [index] [full email
address] [warning level]
get EmailNotifyAddress <index | all>

•

EmailPassword
Configures the password which authenticates the login to the
SMTP Email server. The password must not be more than 64
characters. A password is not required if the Email server does
not require authentication.

set EmailPassword

SaveConfiguration command required

•

EmailServerAddress
Configures the address of the server the unit must contact in
order to send out Email notifications using either an Email
address (xxx.xxx.x.x) or a fully qualified domain name (mail.
myserver.com).

Default: 0.0.0.0
set EmailServerAddress [IP address |domain
name]

SaveConfiguration command required

get EmailServerAddress

•

EmailUsername
Configures the user name which authenticates the login to the
SMTP Email server. The user name must not be more than 128
characters. A user name is not required if the Email server does
not require authentication.

set EmailUsername [username]

SaveConfiguration command required

get EmailUsername

•

EthernetSpeed
Regulates the speed of the RX1600Fibre’s Ethernet port. If

Auto

is enabled, the Ethernet speed is negotiated. When hard set, 10
and 100 speeds are half duplex.

Default: auto
set EthernetSpeed [mp1] [10 | 100 | auto]

SaveConfiguration Restart command required

get EthernetSpeed [mp1]

•

EventLog (Enabled, Disabled on Error)
Regulates event logging. When enabled, records various system
errors to the event log.

set EventLog [enabled | disabled]
get EventLog

•

EventLogFilter (Enabled, Disabled on Error)
Filters data from specific unit subsystems and levels when event
logging is enabled. The specific entries supported are platform-
dependent. For set commands, the final parameter indicates
whether or not events from the specified subsystem and level
are displayed.

set EventLogFilter [subsys | all] [eventlevel |
all] [all | none]
get EventLogFilter [subsys | all] [eventlevel |
all]

• Exit (Immediate)

Terminates the current CLI session over Telnet. This command
has no effect if used during a serial CLI session.

Exit