Sotera FR1118-P10 User Manual
Sotera Equipment
 
1. INTRODUCTION
1.1 Technical Data
1.1.1 The turbine digital meter is designed for use with the 
following low viscosity fluids:
- Water
- Disel exhaust fluid (DEF)
WARNING!
Use of other fluids may be inaccurate and can damage the meter!
1.1.2 Flow Rate: 3-26GPM, flow rates outside of this range 
may have reduced accuracy.
1.1.3 Operating pressure: 4.8BAR/70PSI
1.1.4 Inlet/Outlet: 1”
IMPORTANT!
Not suitable for retail sale of diesel exhaust fluid !
1.2 LCD DISPLAY
The meter display features two numerical registers and 
several function or status indicators.
Fig. 1
1.3 USER BUTTONS
The face of the turbine digital meter has two buttons (MENU 
and RESET) which individually perform two main functions and 
together, other secondary functions.
The main functions performed are:
For the reset key, resetting the partial Register and reset 
table total (reset total)
For the menu key, entering instrument calibration mode.
Used together, the two keys permit entering configuration mode.
1.4 BATTERY REPLACEMENT
The battery in your in-line digital meter is not replaceable. To 
minimize the possibility of fire or explosion, it is a sealed unit 
that does not allow for user replacement. Do not attempt to 
open or replace the battery in your meter.
2. INSTALLATION
The inlet and outlet for this meter is 1
″BSP/NPT. It can be
easily connected with the pipe or nozzle.
1
 
 
 
 
 
 
 
 
 
 
 
 
Wait for the meter to go into standby 
(blank screen).
With the meter in stand-by mode, 
reset the resettable total by 
pressing the “RESET” button.
Press and hold the MENU key until 
the first digit in the display begins 
to flash (approximately 5 seconds). 
The meter is in calibration mode.
Press the RESET key to choose the 
right digit from 0 to 9. Press the 
MENU key to start the next digit. 
So the digit of correction factor 
can be changed one by one.
Make sure the correction factor is 
right, press the MENU key. Keep it 
pressed until quit calibration mode, 
the factor is saved. The meter goes
 to standby again.
1
2
3
4
5
Wait for the meter to go to standby.
Reset the resettable total.
Start dispensing into a measuring 
glass.
Stop dispensing when 5 Litres of 
volume is reached, read out the 
actual value. The volume that is 
displayed on the LCD is the Display 
Value, not the Actual Value which 
may be slightly higher. For example, 
in the figure on the right, the Display 
Value is 18.96 while the Actual 
Value is 20.75.
Press the MENU key. Keep it pressed 
until showed as the right fig., the digit 
flash in 
① zone, Press the RESET
key to choose the right digit from 
0 to 9. Press the MENU key to go 
the the next digit so that the Actual 
Value can be input. 
Make sure the correction factor is 
right and then press the MENU key. 
Keep it pressed until calibration is 
finished and the factor is saved. The 
meter will then return to standby.
1
2
3
4
5
Problem 
LCD: no indication 
Imprecise 
measurement
Reduced or zero 
flow rate
The meter does 
not count, but 
the flow rate is 
correct
Possible Cause
Bad battery contact 
Wrong FACTOR 
The meter works 
below minimum 
acceptable flow rate
Turbine blocked
Incorrect installation 
of turbine after 
cleaning
Possible electronic 
card problems
Corrective Action
Check battery contacts
With reference to 
paragraph 3.3 & 3.4,
check the FACTOR
Increase the flow rate 
until an acceptable 
flow rate range has 
been achieved
Clean the turbine.
Repeat the reassembly 
process.
Contact Tuthill 
Transfer System
No
1
2
3
4
5
6
7
8
Qty.
1
1
2
3
2
1
1
1
Description
Meter Cover
Rubber Protection
Electric Board
Self tap screw 
Self tap screw 
Battery Holder
Battery CR2
Meter Body
No
9
10
11
12
13
14
15
Qty.
4
1
2
2
2
1
2
Description
Self tap screw 
Turbine
Bearing
Bearing holder
Snap Ring
Circuit board
Self tap screw
Description
Resettable Register (5 digit, from 0.1-99999).
Battery condition.
“Calibration” mode.
Resetting current total to 0.
Totalizer Register (total cumulative fluid dispensed).
Rate of flow being displayed.
Unit of measure (liters, gallons, quarts, pints).
#
1
2
3
4
5
6
7
3. DAILY USE
3.1 BUTTON USAGE, CALIBRATION AND MEASUREMENT 
UNIT CHANGE
• Reset the present total (See Fig. 2)
1) When the meter is in standby mode, press the RESET key.
2) The display shows all the segments at once.
3) The meter resets to display “0” on the resettable totalizer.
Fig. 2
• Show current correction factor and general total 
(See Fig. 3)
Press MENU and RESET together and hold for two seconds.
Value “1.4000” is the correction factor which can be reset;
“1234567” is the general total which cannot be reset.
Fig. 3
• Measurement unit change (See Fig. 4) 
Press MENU and RESET together and hold for five seconds. 
Zone 7 on the display is the current unit. Press RESET to 
chose a different measurement unit and then press MENU to 
confirm.
Fig. 4
3.2 RESET THE RESETTABLE TOTALIZER (SEE FIG. 5)
When the meter is in standby, press the RESET key for 2 
seconds to reset the totalizer.
Fig. 5
3.3 Calibration Procedure (Using the Correction Factor)
Carefully follow the procedure indicated below.
FORMULA
Proper correction factor =
current correction factor× (actual value / display value)
Example:
Actual value 20.75 Display value 18.96 
Current correction factor 1.000 
Proper correction factor 
1.000Ч(20.75/18.96)=1.000Ч1.094=1.094
2
3.4 MODIFY THE CORRECTION FACTOR IN FIELD
PLEASE CAREFULLY FOLLOW THE PROCEDURE 
INDICATED BELOW.
3
4. MALFUNCTIONS
5. DIAGRAM AND PARTS LIST
DC000440-000 Rev 0
4
FR1118-P10
User’s Manual
WARNING
Read carefully and understand all INSTRUCTIONS before
operating.
Failure to follow the safety rules and other basic safety
precautions may result in serious personal injury. Save these
instructions in a safe place and on hand so that they can be
read when required.