AUDIO PRE AMPLIFIER

5

PP-6213

8. CHANNEL EQ CONTROLS (3 BAND)

These knobs provide continuous control of equalization up to 12dB boost and cut. Three bands of
equalization are:
Low : 100Hz, Mid : 1kHz, High : 10kHz

9. PRIORITY CONTROLS (PRIORITY 1, PRIORITY 2)

This is the volume controller for the priority input.
When the terminal for the priority is connected to PE-6103(Chime & Siren), locating this controller at more
than 12 o’clock direction is recommended.
- First place : Priority input 1, input 2
- Second place : When ducking is on, channel 1, channel 2
- Third place : other channels (channel 3 to 9)

10. MASTER EQ CONTROLS (4 BAND EQUALIZER)

These knobs provide continuous control of equalization up to 12dB boost and cut. Four bands of equalization
are:
Low : 80Hz, Low-Mid : 400Hz, Hi-Mid : 2kHz, High : 10kHz

11. SUB OUTPUT CONTROLS (SUB1, 2)

Level controller for Sub1 and 2 outputs.

12. POWER SWITCH

Press this switch to turn the unit on, as indicated by the Power LED in the switch. Pressing it again to turn the
unit off.

Advertising