Front panel – Inter-M MA-212U User Manual

Page 6

Advertising
background image

PUBLIC ADDRESS AMPLIFIER

4

MA-206U/212U/224U

Front Panel

Front Panel

1. INPUT 1~6 VOLUME

These knobs provide continuous control of the volume of INPUT 1~6.

※ Volumes of USB-MP3 and AUX can be adjusted through input 6 Volume.

2. INPUT SIGNAL LED

The SIGNAL LED is lighting by input signal of each channel.

3. MASTER VOLUME

This knob provides continuous control of the overall volume of amplifier's output signal.

4. PROTECTION INDICATOR

This LED indicates the state of the amplifier's protection circuitry and MUTE function.
When the protection LED is on (illuminated), the protection circuitry is active, indicating that the unit
is not operating normally.

5. CHIME SWITCH / LED

Pressing this switch will activates the four-tone chime circuitry.

6. SIREN SWITCH / LED

Pressing this switch will activates the siren circuitry.
Pressing it a second will gradually lower the siren signal, turning it off completely after apprximately 2.5 seconds

7. GRAPHIC EQUALIZER

Each slider controls the cut (decreased gain) or boost (increased gain) for its associated frequency band.
The middle position indicates flat response (no cut or boost).
Moving the slider upwards increases that frequency's gain, while moving it down decreases the level
of that frequency.

8. POWER SWITCH (PUSH TYPE)

Pressing the power switch turns the unit on. Pressing it again turns off.

※ This switch makes up that one pole be cut off when power is off.

13

12

1

2

3

11

5

6

7

8

4

10

9

Advertising