MIXING AMPLIFIER

13

PMU-60N/120N/240N

Warning : For high impedance systems, connect with matching transformer as the following Figure. Be

certain that the total impedance does not equal less than the rated impedance.

Please do not use a 4Ω and SP1~SP5 terminal at the same time.

Low Impedance

(100V)

(70V)

PMU-60N

4Ω

167Ω

83Ω

PMU-120N

4Ω

83Ω

42Ω

PMU-240N

4Ω

42Ω

21Ω