Rear panel, Digital power amplifier – Inter-M DPA-300QO User Manual

Page 7

Advertising
background image

DIGITAL POWER AMPLIFIER

5

DPA-300T/300Q, DPA-300TO/300QO

Rear Panel

Rear Panel

1. AC MAINS (AC INLET)

It accepts a standard IEC mains cable, provided

2. DC INPUT TERMINAL

Emergency DC back up power (24VDC) terminal. When AC power is cut off, The unit will operate with DC
power from spare battery pack.
(DPA-TO/QO models are not included with Emergency Power Back Up (24VDC))

3. AC POWER REMOTE

This terminal allows the amplifier to be turned on or off from a distance or other device.

4. COOLING VENTS

Air flow is front to back. DO NOT block front or rear air vents.

5. PRIORITY INPUT AND CONTACT CLOSURE

Each amplifier module has 2 audio inputs. The Primary program input, PGM and Priority input, PRI. The
primary regular broadcast program input, PGM is interrupted and over ridden by the Priority input, PRI,
when a contact closure is received on the PRI select terminal. This is Ideal for Emergency message
broadcasting applications.

6. PRI VOLUME CONTROL

It controls the mute level of all other input signal when the PRI IN signal is present.

7. OUTPUT TERMINAL (CH1, CH2, CH3, CH4)

Speaker Output Terminal with Euro Block.
※ CH4 : Only DPA-300Q/300QO.

+ -

G

+ -

G

+ -

G

+ -

G

CH 4

CH 3

CH 2

CH 1

CH 4

CH 3

CH 2

CH 1

OUTPUT

VOLTAGE

PGM INPUT

70V

100V

OUTPUT

+ -

G

1

2

3

4

COM

PRIORITY

SW

INPUT

PRIORITY

VOLUME

MIN

MAX

+

-

AC INPUT

DC INPUT 21V-27V

MAX 60A

AC POWER REMOTE

1

2

3

4

5

6

7

8

9

Advertising