D. computer logic and wiring diagram, Fault codes – American Dryer Corp. Phase 5 Microprocessor AD-170 User Manual
Page 53
Advertising

49
SEFL
Rotational Sensor Circuit Failure
SEn
Rotational Sensor Selected
SPIn-tInE
Spin Time
Sr
Select Reverse
StoptInE
Stop Time
tEnP-tInE
Temperature Display Time
tinE
Time
Fault Codes
1. door - Keyboard entry was made while the main door or lint drawer was open or fault in the
circuit
2. dSFL - Fault in microprocessor temperature sensor circuit.
3. SEFL - Fault in rotation of basket (tumbler).
4. Hot - Indicates that the dryer has experienced an overheating condition. To cancel the "Hot"
default code, press the "Clear/Stop" key.
D. Computer Logic and Wiring Diagram
1. Operator enters desired selection(s).