Cable testing, Test procedure – IPA Tools 9005A Super MUTT Head User Manual

Page 17

Advertising
background image

17

AUTO SHUTDOWN FEATURE
To preserve battery life, the MUTT

®

enters a Sleep mode if inactive after 20 minutes

with the power On.
• A sound is emitted every 10-20 seconds to inform the operator of the condition.
• Activation of any test mode takes the MUTT

®

out of Sleep mode.

CABLE TESTING

The MUTT

®

has a special cable feature to test 7-way round pin cables for continuity.

The cable testing feature can be used to test a tractor’s cable or the supplied MUTT

®

cable. It is recommended that all cables be tested prior to the MUTT

®

operation.

TEST PROCEDURE

PRIOR TO CABLE TESTING:
To avoid erroneous fault, be certain the 7 pins in each plug are clean and spread to
the proper size.
• Insert each end of the cable into both side connectors on the MUTT

®

. Be sure to

push the cable ends in firmly until they reach the bottom of the connector.
• Turn main power switch to desired power supply.
• Once the power is selected, the green lights around the control knob will blink
and disappear one at a time until only the Ground Integrity light remains solid
green. Once the initial check has been performed, poor cable conditions will be
shown by a blinking light for the problem circuit.
• If the cable has an open circuit or continuity problem, the corresponding circuit
flashes repeatedly.
• Further testing can be performed by selecting each circuit individually via the
control knob or remote. When an open circuit is detected, the LED for the circuit
will flash and an audible alert will be heard.
NOTE: Always check the MUTT

®

connector pins at the side of the MUTT

®

for proper

expansion. Over time, the pins may bend in slightly resulting in a poor connection
between the connector and the cable ends. A flat head screwdriver can be used to
expand the pins until the a tight connection is made.