JuiceGoose RT-5 User Manual

Page 2

Advertising
background image

2

RT-5

REMOTE TURN-ON & TURN-OFF

POWER CENTER

The RT-5 provides a convenient means to remote control a

single component or power strip with a maximum twelve (12)

amp* load. A two position terminal strip on the front connects

to a remote, latching contact closure. This activation design

also allows incorporation of an emergency alarm triggered

turn off. (*The RT-5 has a 15 amp rated circuit breaker and 15

amp rated components.)

SAFETY PRECAUTIONS

The RT-5 is designed to operate on 120 volts, 60 hertz. Operation

with any voltage or frequency other than that can damage the equip-

ment and create an unsafe situation.

CAUTION #1: The RT-5 must be grounded. If a power extension cord is

required, use a properly insulated and grounded cord. Failure to

ground the device could expose user to dangerous electric shock.

CAUTION #2: The RT-5 should be installed and used with only appro-

priate mounting hardware in a manner described in this document.

CAUTION #3: Do not expose the RT-5 to moisture or salty air. Doing

so could cause significant damage and create an unsafe condition.

DISCLAIMER

Juice Goose shall under no circumstances be held responsible for any

losses, damage, or injury resulting directly or indirectly from the use

of the RT-5 in a manner contrary with accepted safe operating meth-

ods or any instructions contained in this document. The user should

determine prior to use whether this product is adequate, suitable and

safe for the application intended. Since individual applications can be

subject to extreme variation Juice Goose makes no representation or

guarantee as to the suitability of the RT-5 for any generally de-

scribed application.

3

RT-5

DETAIL SPECIFICATIONS

CHASSIS……................................…..................….16 Gauge, Powder Coated Steel

DIMENSIONS (inches)...............................................................4.0H x 5.0W x 3.25D

WEIGHT (lbs)….………..……….......................................…………………………...2.0

CIRCUIT BREAKER…...….….....................................….................................15A Thermal

POWER INPUT......…..................……...7 Foot, 14/3 SJTW with NEMA 5/15P

VOLTAGE INPUT….................…...................………....………….120 VAC at 60 Hz

POWER OUTPUT RECEPTACLE.............................................Single NEMA 5/15R

REMOTE CONTROL CONTACT

Two Position Phillips Screw Terminals

Wire Size.............................................................................................24 to 12 AWG

INPUT RELAY

Coil Rating.......................................................................11 mAmps @ 40 Ohms

Contact Rating................................................................................................15 Amps

NEMA 5-15R

12 VAC

CIRCUIT BREAKER

MAIN

POWER

120VAC

12VAC RELAY

JUMPER FOR

REMOTE CONTROL

RT-5

SCHEMATIC

REMOTE

CONTROL

CONTACTS

Advertising