INSTALLATION INSTRUCTIONS

SAVE THESE INSTRUCTIONS

OWNERS GUIDE & INSTALLATION INSTRUCTIONS SHOULD BE LEFT WITH HEATER FOR HOME OWNER

KING ELECTRICAL MFG. COMPANY • 9131 10th Ave So. • Seattle, WA 98108 • Ph: 206.762.0400 • Fax: 206.763.7738 • www.king-electric.com

It is ALWAYS recommended to order your unit with or without the thermostat for your particular application. If your unit

has been ordered incorrectly please contact the factory and we can exchange it for the proper unit. Adding a built-in

thermostat after installation is complicated and could result in creating wiring errors and shorting out this unit.

Instructions for wall mount heater

It is extremely important to verify the electrical power supply is the same voltage as the heater you are installing. 240 and
120 Volt heaters are not interchangeable.
Powering a 240 Volt unit with 120 Volt supply wires will reduce the heater's output
by approximately 75%. Powering a 120 Volt unit with 240 Volt supply wires will destroy the heater and voids all warranties.

NOTICE: For heaters without built-in thermostats - using remote or wall mounted thermostats. The power must be brought to
the heater first (not to the wall mounted or remote thermostat). This is necessary to provide power for the fan to cool down the
element after the thermostat has opened. Use only a single pole line voltage wall thermostat or switch to control this heater.

CAUTION: Disconnect the circuit breaker supplying the heater before attempting installation, maintenance, or repairs.
Lock or tag circuit breaker panel door. Failure to do so could result in serious electrical shock, burns, or possible
death.

1. Remove heater contents from carton and check for

shipping damage.

2. Remove grill by loosening the four mounting screws along the

sides of the front panel.

3. Detach interior assembly from the wall can by removing the four

screws along each side of the interior panel. Lift and tilt assembly

away from the top of the wall can. Free the bottom edge from the

metal lip inside the wall can. Place the interior assembly in a safe

location until the wall can is mounted.

4. Remove one knockout from the wall can and thread supply wires

through the hole. Use an approved cable connector to prevent

wires from chafing. Connect groundwire to green pigtail.

5. Mount heater wall can on wall studs a minimum of 6" from side

wall and 10" from floor, using the holes provided in the sides of

the box. The face of the box should be flush with the finished

wall. Installation of the interior and grill to the wallbox cover an

approximate 5/8" periphery along the outer area of the opening.

6. After wall can is secured interior assembly leads may be attached supply wires

and interior secured to wall can. NOTE: The LPW wall heater is equipped with

two steel elements having a combined capacity of 2750 Watts. The heater is

factory wired at 2750 Watts. To adjust the heater for lower wattages remove

the appropriate colored wire according to the illustration and wattage diagram

provided on the back side of this sheet. Be sure to insulate and secure the

unused lead.

7. Reinstall interior assembly on wallbox using screws provided.

8. Mount grill to interior with screws provided.

LPW1227 120 VOLT MODEL

Maintenance & Warranty

The high quality and superior design of this unit will enable years of maintenance-free performance. Once yearly

the heater should be checked for lint or dust accumulation but no further maintenance is required. The motor is

permanently lubricated and sealed. A five year warranty is provided on the Pic-A-Watt

®

element and 1 year on all

materials, components and workmanship.

VISUAL ALARM

This heater includes a visual alarm to warn that
parts of the heater are getting excessively hot.
If the alarm flashes immediately turn the heater
off and inspect for any objects on or adjacent to
the heater that may cause high temperatures.
Do not operate the heater with the alarm
flashing.