LevelOne FVT-0103TXFC User Manual
Page 3

LFP
TP-AUTO 100 FDX EN FDX-FX
S1
1
2
3
4
5
TP-FORCE 10 HDX LFP HDX-FX
DIS
Fig. 11 S1—Bit 1, 2, 3, 4, 5 Configuration and Setting
S1-1 TP port mode :AUTO(default) or FORCE
S1-2 TP port speed :100 or 10 when TP at Force
S1-3 TP port duplex :FDX or HDX when TP at Force
S1-4 LFP:LFP enabled(default) or disabled
S1-5 Fiber port duplex:100FDX(default) or 100HDX
Note:
1. S1-2 and S1-3 will take effect only when S1-1 is set
at TP-FORCE.
2. S1-5 must be set to 100FDX for Single Fiber Model.
Warning:
ۛ When TP NWay port is connected to TP 100FDX(force
mode) instead of NWay partner, it will result in 100HDX
mode with invalid collision signal
ۛ Ensure that all network nodes are configured at an
identical operation mode. Improper operation and flow
control mode between TP and Fiber port connections will
render the LAN to work poorly
9. Cable Connection Parameter
100Base-X network allows 512-bit time delay between any
two node-stations in a collision domain. Switch-based Media
Converter breaks up TP and Fiber segments’ collision domain
to extend the cabling distance.
• TP Cable Limitations: Cat. 5 and up to 100m
• Converter Fiber Cable Limitations:
FVT-0103TXFC
Multi-mode Half-duplex
Multi-mode Full-duplex
412m
2Km
9