LevelOne IED-1020 User Manual

Page 55

Advertising
background image

Device Server.

Port
1. Virtual COM
 Step 1: Xport mode
Choose

“Virtual Com” from the “Step 1: Xport mode”.

Fig 76. Virtual COM

 Step 2: Serial port settings
Baud rate:

Click “Baud rate” drop-down menu to select Baud rate 50 ~ 460800bps from the

“Baud rate” drop-down list for the serial port. The default Baud rate of the serial port is
9600bps.

Data bits:

Click “Data bits” drop-down menu to select Data bits 5, 6, 7, or 8 from the “Data bits”

drop-down list for the serial port. The default Data bits of the serial port is 8 bits.

Stop bits:

Click “Stop bits” drop-down menu to select Stop bits 1 or 2 from the “Stop bits”

drop-down list for the serial port. The default Stop bits of the serial port is 1 bit.

Parity:

Click “Parity” drop-down menu to select Parity None, Even, Odd, Mark, or Space from

the “Parity” drop-down list for the serial port. The default Parity of the serial port is None.

Flow control:

Click “Flow control” drop-down menu to select Flow control None, Hardware, or

Software from the “Flow control” drop-down list for the serial port. The default Flow control of
the serial port is None.

Mode:

Click “Mode” drop-down menu to select Mode RS232, RS422, or RS485 from the

“Mode” drop-down list for the serial port. The default Mode of the serial port is RS232.

 Step 3: Protocol timeout setting
Support protocol timeout auto-detect: Check this option to support protocol timeout
auto-detect. The Serial Device Server will automatically test the TCP connection to remote
host. If the TCP connection is idle, the TCP connection will be closed and the port will be freed
for other hosts.

Protocol timeout:

Click in “Protocol timeout” text box and type a period of Protocol timeout