LevelOne HVE-6501T User Manual

Page 12

Advertising
background image

EDID usage.
During multicast setup, there maybe monitor/TV that
has lower resolution. For example, 1 monitor/TV with
720p resolution with mostly 1080p solutions. Please
select the monitor/TV with lowest resolution, to ensure
all can be displayed correctly.
For customer that are using 1 pair of Host/Client with
Multicast mode, the end user must update EDID
correctly. If not, it will cause many compatibility issue.
Operation:
Once the button event is triggered correctly at the client
side, when system is setup correctly for Multicast. The
selected EDID will be update to Host Side EEPROM.

Firmware Upgrade Mode

1. Static IP: 192.168.0.88
2. User can connect to http://192.168.0.88 webpage for
firmware update.
3. Firmware update file name will be:
Host :webfwh.bin
Client :webfwc.bin

Reset to Default

1. Reset Any changes in SPI flash setup flag.
2. After Reset to Default and reboot cycle, will use
default setting.


How to Use RS232 over IP

HVE-650/660 series support a feature called "RS232 over IP". This feature redirects
RS232 data from client/host to host/client. the RS232 redirection is automatically
established between host and clients. There is no need to explicitly issue
commands for establishing redirection. The FW code will automatically link the
host and clients all together using a pre-configured baudrate setting (default is
9600-8n1). Normally, this static baudrate setting is pre-configured on
Manufacturing. Also you can change baudrate setting by Link Utility, you can refer to
next chapter.