3

MAINTENANCE

The following should be checked by an authorized LiftMaster dealer:

BATTERIES

Batteries will degrade over time depending on temperature and usage. For best performance, the batteries should

be replaced every 3 years. Use only LiftMaster part 29-NP712 for replacement batteries. The operator comes with

two 7AH batteries. Two 33AH (A12330SGLPK) may be used in place of the 7AH batteries.
The batteries contain lead and need to be disposed of properly. Batteries do not perform well in extremely cold

temperatures.

NOTE:

If your application includes a heater, two 33AH will not fit into the operator enclosure (swing only).

The operator alarm will beep 3 times with a command if the battery is low.

DRIVE CHAIN (SLIDE ONLY)
Over time, the drive chain on the operator will stretch and need to be tightened. To tighten the drive chain adjust

either of the two chain eye bolts.

NOTE: The chain should have no more than 1 inch of sag for every 10 feet of chain length.

CHECK AT LEAST ONCE EVERY MONTH

DESCRIPTION

TASK

Entrapment Protection Devices

Check and test for proper operation

Warning Signs

Make sure they are present

Gate

Inspect for wear or damage

Drive Chain (Slide Only)

Check for excessive slack and lubricate

CHECK AT LEAST ONCE EVERY

DESCRIPTION

TASK

6 MONTHS

3 YEARS

Manual Disconnect

Check and test for proper operation

X

Sprockets and Chains

Check for excessive slack and

lubricate

X

Belt and Pulley (Slide

Only)

Check for excessive slack, wear, or

damage

X

Accessories

Check all for proper operation

X

Electrical

Inspect all wire connections

X

Chassis Mounting Bolts

Check for tightness

X

Operator

Inspect for wear or damage

X

Batteries

Replace

X

Advertising