Standard features, Optional features, Technical data – Southern Folger 10300E SOLENOID OPERATED ELECTRO-MECHANICAL DEADLATCH User Manual
Page 2
P.O. BOX 2021 • SAN ANTONIO, TX • 78297 • 210-533-1231 • FAX: 210-533-2211
Revised 3/09
10300E SOLENOID OPERATED
ELECTRO-MECHANICAL DEADLATCH
STANDARD FEATURES:
•
Deadlock indication switch
•
Mechanical latchback
•
Strike with security fasteners
•
Faceplate with security fasteners
•
Plug connector
•
High power, dual coil solenoid
with overload protection device
•
Fail secure
•
Mounting fasteners
Note #1: 1-11/16” O.D. x 1/8” wall
cold drawn tubes furnished by
hollow metal manufacturer.
OPTIONAL FEATURES:
NO LATCHBACK - Latchbolt
remains retracted as long as
control switch is activated.
Latchbolt extends when power is
removed. Specify “NL.”
LOCAL ELECTRIC KEYSWITCH -
Day key provides local electric
operation and may be disabled
from remote control point. Master
key provides both electric and
mechanical operation.
Requires
dual-function enhancement to builder's
cylinder.
Specify “LEK.”
BUILDER’S HARDWARE
CYLINDERS -
Specify:
• “10300E-1” keyed one side.
• “10300E-2” keyed both sides.
KEY CYLINDER EXTENDER -
Required whenever lock is keyed
on stop side. Overall frame depth
4" minimum. Specify “KCE.”
Full body rim cylinder required on stop side.
Full body mortise cylinder required on
hinge side.
PROVIDE: (See Fig.1)
1. Dimension “A”
(overall frame width)
2. Dimension “B”
(edge of frame to centerline of lockbolt)
TECHNICAL DATA
• STANDARD FINISH: US32D
• LOCK BODY: Stainless steel
• FACE PLATE: Stainless steel
• LATCHBOLT: Stainless steel
• DEADLOCK ACTUATOR:
Stainless steel
• ELECTRICAL:
24 VDC, 7.0 amp inrush,
0.6 amp seated
• LOCK SIZE:
10-5/8” H x 1-1/2’ W x 1-3/4” D
• LOCK WEIGHT: 3.6 lbs.
• LATCHBOLT SIZE:
1-5/8" H x 5/8" TK
• LATCHBOLT THROW: 3/4"
• BUILDER’S CYLINDER:
1-5/32” diameter with
standard Yale cam
or equal
• UL Listed for use on
three-hour fire doors.
• ASTM F1577 Certified
Impact Test-Grade 1
Frame Preparation
NOTE: Drawing for illustration only. Reference template
for specific Information.
Swing Chart:
Specify circled swing number when ordering.
B14
E L E C T R I C L O C K S
JAMB MOUNTED FOR
SWINGING DOORS
Minimum and medium security.
1-11/16” O.D. x 1/8”
wall cold drawn tubes
are required.
See Note 1