STANDARD FEATURES:

• Deadlock indication switch
• Mechanical latchback
• Strike with security fasteners
• Faceplate with security fasteners
• Plug connector
• High torque motor
• Fail secure
• Mounting fasteners
Note #1: 1-11/16” O.D. x 1/8” wall

cold drawn tubes furnished by

hollow metal manufacturer.

OPTIONAL FEATURES:

HALF CYCLE HOLDBACK -
Remote two-position maintained
contact switch is required for this
function. Latchbolt is retracted
electrically when switch is in open
position. When remote switch is
returned to locked position, latch
bolt will extend when door is
opened approximately 2".
Specify “D.” UL listing not
available with this function.

NO LATCHBACK - Allows latch
bolt to extend without opening
door. Normally used with “D”
function. Specify “NL.”

LOCAL ELECTRIC KEYSWITCH -
Day key provides local electric
operation and may be disabled
from remote control point. Master
key provides both electric and
mechanical operation. Requires
dual-function enhancement to
builder's cylinder. Specify “LEK.”

BUILDER’S HARDWARE
CYLINDERS -
Specify:
• “10300M-1” keyed one side.
• “10300M-2” keyed both sides.

KEY CYLINDER EXTENDER -
Required whenever lock is keyed
on stop side. Overall frame depth
4" minimum. Specify “KCE.”
Full body rim cylinder required on stop side.
Full body mortise cylinder required on
hinge side.
PROVIDE: (See Fig. 1)

1. Dimension “A” (overall frame width)
2. Dimension “B” (edge of frame to

centerline of lockbolt)

10300M MOTOR OPERATED

ELECTRO-MECHANICAL

DEADLATCH

TECHNICAL DATA:

• STANDARD FINISH:

US32D

• LOCK BODY:

Stainless steel

• FACE PLATE:

Stainless steel

• LATCHBOLT:

Stainless steel

• DEADLOCK ACTUATOR:

Stainless steel

Frame Preparation

NOTE: Drawing for illustration only. Reference template

for specific Information.

Swing Chart:

Specify circled swing number when ordering.

• ELECTRICAL: 24 VDC

, Inrush: .3A

Locked Rotor Current: 1.5A

• LOCK SIZE:

10-5/8” H x 1-1/2” W x 1-3/4” D

• LOCK WEIGHT: 3.6 lbs.
• LATCHBOLT SIZE:

1-5/8" H x 5/8" TK

• LATCHBOLT THROW: 3/4"
• BUILDER’S CYLINDER:

1-5/32" diameter with
standard Yale cam or equal

• UL Listed for use

on three-hour fire doors.

• ASTM F 1577 Certified