Troubleshooting contacting technical support – Staub Electronics ECA-70MIXAMP-1-60 EPISODE - 60 WATT RACK MOUNTABLE 70 VOLT COMMERCIAL AMPLIFIER-MIXER User Manual

Page 10

Advertising
background image

pg. 10

ECA-70MIXAMP-1-60 Installation Manual

Troubleshooting

Contacting Technical Support

Note: If any of the troubleshooting methods listed above do not resolve the issue, please contact our Technical Support department.

Phone: (866) 838-5052
Email: [email protected]

Amp will not turn on.

Power cable to the amplifier is incorrectly connected or plugged into an

outlet that does not have power. Check connections and verify power

on the outlet.

Main Power Fuse is blown. Replace fuse and ensure power outlet is

providing the correct power and polarity for the amplifier.

TEMP LED is lit.

Amplifier is overheating. Install per instructions in manual, “Positioning

the Amplifier”.

PROT LED is lit

Short circuit on input or output. Verify all wiring and connections.

Too much current is being drawn on speaker output. Calculate load

attached to amp and configure so that impedance or wattage output is

within specification.

Hum or buzzing sound is heard.

Check RCA input cables by removing them one at time (powering down

the amplifier before disconnecting) and checking to see if a connection

or cable is to blame.

No audio from speakers.

If output meter is active, then amplifier is processing signal but output is

in protection. See section above, “PROT LED is lit.”

If output meter is not active, then the amplifier is not receiving audible

signal. Verify correct source operation ad input wiring. Turn Input or

Master volume up to an audible level.

Amplifier is in temperature protection. See section above, “TEMP LED

is lit.”

No sound from microphone input

Set the phantom power switch to the correct mode for microphone.

Verify wiring configuration and power requirements with microphone

manufacturer.