Mounting, 2 wiring method, wiring distance, 3 cable – Aiphone JK-1SD User Manual

Page 3: Ab c

Advertising
background image

- 3 -

English

Fr

ançais

Español

Neder

lands

Italiano

2-2 Wiring method, wiring distance

Wire the inside units from station-to-station (daisy-chained).

JK-1SD

JK-1MED/1MD

JK-DA

JK-DV

JK-DVF

2

4

PS18

PS-1820

PS-1810DIN

PS-1820DIN

A

B

C

IER-2

2-3 Cable

1

Use PVC-coated cable with PE (polyethylene) insulation.

(x2)

2

Never use individual conductors, twisted pair cable or coaxial cable.

3

When using a cable with unused conductors, terminate both ends of

the unused pair(s) with a 120 resistor .

JK-1MED/1MD

JK-1SD

120

120

+

-

A1

A2

B1

B2

L
L

S
S

+
-

SW

SW

B1

B2

Ø 0.65 mm

22 AWG

Ø 1.0 mm

18 AWG

A

50 m

165'

100 m

330'

B

5 m

16'

10 m

33'

C

75 m

245'

150 m

490'

3

MOUNTING

Mounting on a gang box

1

2

Mounting
screws x 2

1-gang box

UP

Wall mounting bracket

83.5 mm
(3-5/16")

8 mm

3/8"

1. Press RELEASE button. (This is performed to

release the lock or to securely insert wiring.)

2. Insert the cable into the terminal.

Surface wiring

UP

Wall mounting bracket

83.5 mm
(3-5/16")

Wood mounting screws x 2

JK-1SD_multi.indb 3

2008/12/12 0:09:21