Specifications, Nominal characteristics, Warranted characteristics – Teledyne LeCroy CP031 User Manual

Page 20: Typical characteristics

Advertising
background image

CP031 Current Probe

14

923362-00 Rev A

Specifications

Nominal Characteristics

Nominal characteristics describe parameters and attributes which are guaranteed by design, but do not
have associated tolerances.

Maximum Continuous Input Current

30 A

rms

(Refer to Figure 3)

Maximum Peak Current

50 A

peak

, noncontinuous

Insertion Impedance

Refer to Figure 4

Intended Output Load

1 MΩ

Maximum Permitted Circuit Voltage

300 V, CAT I (Insulated conductor)

Warranted Characteristics

Warranted characteristics describe parameters which have guaranteed performance. Unless otherwise
noted, tests are provided in the Performance Verification Procedure for all warranted specifications.

Guaranteed at 23 °C ±5 °C (73 °F ±9 °F) after power has been applied for 30 minutes.

Amplitude Accuracy

±1.0% of reading ±10 mA; to 30 A

rms

±2.0% of reading; to 50 A

peak

(DC, 45 to 65 Hz)

Typical Characteristics

Typical characteristics describe parameters which do not have guaranteed performance; however are
representative of the average performance from a sample of several probes. Tests for typical
characteristics are not provided in the Performance Verification procedure.

Sensitivity*

20 mA/div* to 50 A/div.

Output voltage

0.1 V/A

Sensitivity Temperature

±2% or less. (from 0° to +40 °C,

Coefficient

32 °F to 104 °F)

Noise

Equivalent to 2.5 mA

rms

or less

(BW of measuring instrument: 20 MHz)

Bandwidth

DC to 100 MHz.

Rise Time

≤ 3.5 ns

* Lower sensitivity may change with different oscilloscope models.

Advertising