Teledyne LeCroy UWBSpekChek and WiMedia Platform Test User Guide User Manual
Page 22

UWBSpekChek™ WiMedia Platform Compliance
Test Guide
rev3.10
2
Page 22 of 33
• Devices are allowed to keep their reservation as long as they don’t transmit in a
reserved MAS
• The DUT and INTD are allowed to stop demonstrating operation and/or beacon
transmission once the conflict is created
LeCroy UWBTracer Superframe Grid View shows MAS slots reserved for each superframe.
Test Case 2.2: TD.8.1.4.2 Conflicting Reservation – DUT Reservation Only – Alien DRP
This test verifies that the DUT follows reservation size and location rules when it
operates on an empty channel.
Test procedure:
1.
Start analyzer capture.
2.
Test system starts transmitting a beacon with no reservations in slot 2. The BP
Length is set to 12.
3.
Standard test start-up sequence.
4.
The test system begins to transmit a beacon in slot 5 that contains DRP IEs that
reserve the top and bottom rows in the superframe. The reservation is of type
Alien DRP.
5.
After 2 seconds, test system stops beaconing.
6.
After at least 2 seconds, stop analyzer capture.