13

To convert the read data to voltage and current use the following equations:

Read Data (decimal) * 2.26 * 2.5/4096 = all voltages and currents in Volts and Amps, except 12V voltage.
Read Data (decimal) * 5.75 * 2.5/4096 = for 12V voltage only


15- Select +5V ramp:


Use the "Set Address" routine to set address

DUT 1 = 0x7c

DUT2 = 0xfc

use write routine.

0x0 = slow; 0x1 fast