3RM/24VAC

Installation Instructions

3RM/24VAC Three Relay Module (24 Vac/dc) Installation Instructions TG200647 Issue1/C 02/04/07

4

Manufactured for and on behalf of the Environmental and Combustion Controls Division of Honeywell Technologies Sàrl, Ecublens, Route
du Bois 37,Switzerland by its Authorized Representative, Trend Control Systems Limited.

Trend Control Systems Limited reserves the right to revise this publication from time to time and make changes to the content hereof
without obligation to notify any person of such revisions or changes.

Trend Control Systems Limited

P.O. Box 34, Horsham, West Sussex, RH12 2YF, UK. Tel:+44 (0)1403 21888 Fax:+44 (0)1403 241608 www.trend-controls.com

Trend Control Systems USA

6670 185th Avenue NE, Redmond, Washington 98052, USA. Tel: (425)897-3900, Fax: (425)869-8445 www.trend-controls.com

WEEE Directive :

At the end of their useful life the packaging and product should be disposed
of by a suitable recycling centre.
Do not dispose of with normal household waste. Do not burn.

1 2 3 4 5 6 7 8 9 10

A

B

C

D

DP

TX

RX

OK

LAN

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

V

24V

16

17

18

19

20

IN

0V

24V

A

U

T

O

ON

O

F

F

A

UT

O

ON

O

F

F

H

T

J2

J1

FAN/

LOW

COOL/

MID

RL1

RL2

NO

NC

C

N

O

NC

C

HEA

T/HIGH

RL3

NO

NC

C

AU

TO

O

N

OF

F

J3

3

INSTALLATION

(continued)

Close panel

12

Switch on IQ

13

14

IQ

‘click’

IN 0V 24V

AUTO ON OFF AUTO ON OFF

H
T

J2

J1

FA

N/LOW

COOL/MID

RL1

RL2

NO

NC

C

NO

NC

C

HEAT/HIGH

RL3

NO

NC

C

AUTO ON OFF

J3

1

2

3

4

5

6

7

8

9

1 0

A

B

C

D

D P

T X

R X

O K

L A N

1

2

3

4

5

6

7

8

9

1 0

1 1

1 2

1 3

1 4

1 5

V

2 4 V

1 6

1 7

1 8

1 9

2 0

O

I

IQ

O

I

3RM

Power Supply

Check Relay operation

15

3RM

Note that the AUTO/ON/OFF links may be used to test 3RM to HVAC Equipment installation,
however, when using manual overrides (ON, OFF), feeds switched from other relays on the same
module, or interlocks with other relays may not be operative.

HEAT/HIGH

‘click’

FAN/LOW

‘click’

COOL/MID

This unit is UL rated
as ‘UL916 listed
accessory to open
e

n

e

r

g

y

m a n a g e m e n t
equipment.’

Switch on Equipment input
power supply

Input power

supply

Equipment

Equipment

4

DISPOSAL

Configure IQ

11

It is recommended to use SET (software
tool) for configuring the controller. SET is
suppied with 3RM strategy blocks for IQ1,
IQ2, and IQ3 controllers. These can be
used as they are or as examples
There are 3 strategy blocks: HCM mode,
TRM mode/analogue driver, HCM mode/RL
driver