IQView../RPM Installation Instructions TG200712 Issue 1/F 10/01/07

Important: Retain these instructions

Installation Instructions

IQView../RPM

Rear Panel Mounting Touch Screen Display

1 - 1

IQVIEW/P ANEL Installation Instructions - Template TG200723 Issue 1/A 5/11/03

Installation Instructions - T emplate

IQVIEW/PANEL

Touch Screen Display

Important: Retain these instructions

IQVIEW/P ANEL

Installation Instructions - T emplate

Trend Control Systems Ltd reserves the right to revise this publication from time to time and make changes to the content hereof
without obligation to notify any person of such revisions or changes.

Trend Control Systems Ltd P.O. Box 34 Horsham Sussex RH12 2YF England Tel:+44 (0)1403 211888 Fax:+44 (0)1403 241608 www.trend-controls.com

10 cm

4"

NOTE: Print to size.
Check dimensions below

132 m m (5.2" )

10

3

mm

(4

.06

"

)

display cutout clearance dim ensions

cutout for display

A

A

A

A

A mounting hole centres

VIEW FROM FRONT

2 Storing

60.62 mm (2.39")

234 mm (9.21")

208 mm (8.19")

Dimensions

Requirements

a

H

2

O

0 °C

(32 °F)

+45 °C

(113 °F)

0 %RH

80 %RH

c

1

2

H

2

O

+50 °C

(122 °F)

0

-10 °C

(14 °F)

90 %RH

CONTENTS

1

Unpacking ........................................................................... 1

2

Storage ............................................................................... 1

3

Installation Instructions ...................................................... 1

3.1 Installation - Mounting ......................................................... 1
3.2 Installation - Configuration ................................................. 6
4

Disposal ............................................................................ 10

5

End User Licence Agreement .......................................... 11

IQView../RPM
Installation Instructions
TG200712

1 Unpacking

3 Installation Instructions

3.1 Installation - Mounting

Protection: IP54, NEMA3
(if correctly fitted in panel)

The unit is UL rated as 'UL916, open energy
management equipment'

cable and terminal access

b

65 mm (2.56")

d

!

WARNING
Do not attempt to open the unit. Failure to
comply may cause damage to the unit

IQView Manual
TE200719

IQView../RPM Template
TG200723

It is recommended that the installation should
comply with the HSE Memorandum of Guidance
on Electricity at Work Regulations 1989.

For USA install equipment in accordance with
National Electric Code