4.0 DIAGNOSTICS, VERIFICATION, AND TROUBLESHOOTING

4.1

Performing an H and X Cable Diagnostic Test

Use the steps below to perform a diagnostic test on the H and X cables:

a. Start from the “START-UP” menu:

Press the

[4]

key (DIAGNOSTIC).

b. The following screen will be displayed:

Press the

[1]

key (CABLE TEST).

c. The following screen will be displayed:

Connect the H and X cables per the on-screen instructions and then press the

[ENTER]

key.

d. The following screen will be displayed while the cables are being tested:

cable test






cable test

CONNECT: H0-X0, H1-X1
H2-X2, H3-X3

"ENTER" TO CONTINUE..

1.

CABLE TEST

2.

VERIFICATION TEST




1.

RUN TEST

2.

SETUP

3.

TEST PLANS

4.

DIAGNOSTIC


TIME: 15:45:15