20 hood service procedures – XLT XD-9007A (ELEC Oven Version – D, AVI Hood Version – C) User Manual

Page 20

Advertising
background image

Technical Support US: 888-443-2751

Technical Support INTL: 316-943-2751

20

HOOD SERVICE PROCEDURES

Complete VFD manual available at

www.xltovens.com

.

Hitachi X200 Restoring AVI Defaults

Access program parameters by pressing the <FUNC> button one time and using the up and down
arrow buttons to navigate to the appropriate parameter. Press the <FUNC> button again to make
adjustments to that parameter by using the up and down arrows. To store the new settings press the
<STR> button one time.

B031 = 01
B084 = 01

Press and hold the <FUNC> <Down Arrow> and <Stop/Reset> buttons all at the same

time. Release the buttons all at once and the country code should appear in the dis-
play (USA). Hitachi’s factory settings are now restored.

To install AVI Defaults press <FUNC> button one time and enter following parameters

A001 = 01
A003 – USA = 60 Hz.

World = 50 Hz.

A082 = Supply voltage at

location 200, 215, or

230 choose appropriate

voltage.

A093 = 3000
A094 = 01
A096 = 10
B002 = 25
C001 = 02
C002 = 03
C003 = 04
C004 = 05
C014 = 00
F001 = See Figure 1
H004 = 4
B031 = 03

Put controller into display mode by pressing the <FUNC> button and holding until d001 appears

on the display release and then press the <FUNC> button one time. The display should show
0.0.

Test run the motor by turning on one of the oven/hood switches located on the face of the hood.

Read the entire instruction before programming.

TIP