Carry out the connection in such a way as does not cause any stress whatsoever on the appliance.

The gas supply connector is threaded G½” (fig.12).

For ISO R7 connections, the gasket is not required.

For ISO R228 connections, the washer supplied must be fitted.

After connection operations, check for leaks using a soapy solution.

Electrical connection

Before connecting the appliance to the electricity supply, check that the voltage corresponds to that on the

data plate and that the power supply cable is suitable for the appliance load also stated on the data place.

If the appliance is connected directly to the mains, fit an all-pole disconnect switch with minimum

contact gap of 3 mm, adequate for the appliance load and complying to regulations.

The plug used must support the power of work of the appliance.

Warnings:

-

Do not use reducers, adapters or switches for connection to the mains, since these

could overheat and cause burns.

-

Earth connection is required by law (fig.10).

The manufacturer declines all liability resulting from failure to observe this regulation.

If the power cable must be replaced, use a cable having identical characteristics to the original

supplied by the manufacturer, suitable for the load and temperature (type T90°C). This is available

from After-sales service. Furthermore, the end of the power cable to be connected to the appliance

must have the Yellow-Green earth conductor 20 mm longer than the other conductors.

The cable must support the load of the appliance.

Should it be necessary to replace the supply cord,

connect the wire in accordance with the following colours/codes:
BLUE

NEUTRAL (N)

BROWN

LIVE (L)

YELLOW-GREEN

EARTH ( - )

-

Check wether there is a omnipolar switch available on the domestic line which is compliant with

current standards laws.

Otherwise, place a device easily reachable between the appliance and the electricity line.

-

If the cable result damaged, it must be quickly replaced with a new one by a qualified technician

or call the After-Sales service.

If a different type of gas from the one indicated on the rating plate is used, the injectors must be replaced.

If spare injectors are not supplied with the appliance, they are available from the After-sales service.

For the choice of replacement injectors, refer to the injectors table at the end of this booklet.

The injectors are identified by their diameter, which is expressed in hundredths of mm, stamped on

the body of the injector itself.

Replacing the injectors

-

Remove the grids and burner caps from the cooktop

-

Using a socket wrench, replace the injectors “J” (fig.9) with the suitable ones for the gas used

-

Replace the burners

The burners do non require primary air adjustment.

ADJUSTMENT TO DIFFERENT TYPES OF GAS