Aptio Setup Utility – Copyright (C) 2011 American Megatrends, Inc.

Advanced

Smart Fan Mode Configuration

FAN 1 Smart Fan Control

[Auto Duty-Cycle Mode]

Temperature 1

60

Temperature 2

50

Temperature 3

40

Temperature 4

30

Duty Cycle 1

85

Duty Cycle 2

70

Duty Cycle 3

60

Duty Cycle 4

50

FAN 2 Smart Fan Control

[Auto Duty-Cycle Mode]

Temperature 1

60

Temperature 2

50

Temperature 3

40

Temperature 4

30

Duty Cycle 1

85

Duty Cycle 2

70

Duty Cycle 3

60

Duty Cycle 4

50

FAN 3 Smart Fan Control

[Auto Duty-Cycle Mode]

Temperature 1

60

Temperature 2

50

Temperature 3

40

Temperature 4

30

Duty Cycle 1

85

Duty Cycle 2

70

Duty Cycle 3

60

Duty Cycle 4

50


Smart Fan Mode Select


















---------------------
: Select Screen
↑ ↓: Select Item
Enter

Select

+ - Change Opt.
F1

General Help

F2

Previous Values

F3

Optimized Defaults

F4

Save & Exit

ESC Exit

Version 2.14.1219. Copyright (C) 2011 American Megatrends, Inc.

BIOS Menu 16: FAN 1 Configuration

 FAN 1 Sm a rt Fan Co n tro l [Au to Du ty-Cyc le Mo d e ]

Use the FAN 1 Smart Fan Control option to configure the FAN 1 Smart Fan.

Manual RPM

Mode

The fan spins at the speed set in Manual by

RPM settings

Manual Duty

Mode

The fan spins at the speed set in Manual by Duty

Cycle settings

Auto RPM Mode

The fan adjusts its speed using Auto by RPM

settings