Instructions for the installer, Engineers technical data – AEG 35601G User Manual

Page 12

Advertising
background image

12

OVERALL DIMENSIONS

Width:

580 mm.

Depth:

500 mm.

Height:

88 mm.

Weight:

8 Kg.

CUT OUT DIMENSIONS

Width:

550 mm.

Depth:

470 mm.

Thickness:

30 mm.

SUPPLY CONNECTIONS

Gas:
RC 1/2 inch (1/2 inch male) Rear right hand corner
Electric:
230-240V 50Hz supply, 3 core flexible cable with
non rewireable plug fitted with a 3 amp cartridge fuse.

IGNITION HT SPARK

Spark Generator
Ispra Control's BF 50046 - 230-240V 0.6 YA T120
Spark Gap : Fixed

HEAT INPUT

Rear Left Burner

2.0 kW (6824 BTU/HR)

(semi rapid)

Front Left Burner

3.0 kW Natural Gas (10236 BTU/HR)

(rapid)

2.8 kW L.P.G. (9554 BTU/HR)

Rear Right Burner

2.0 kW (6824 BTU/HR)

(semi rapid)

Front Right Burner

1.0 kW (3412 BTU/HR)

(auxiliary)

APPLIANCE CLASS

3

APPLIANCE CATEGORY

II2H3+

GAS SUPPLY

Natural gas G20 / 20mbar

Instructions for the Installer

Engineers technical data

Advertising
This manual is related to the following products: