Installation – Lincoln Electric IM10132 FLEXTEC 650 User Manual
Page 11

A-5
INSTALLATION
A-5
FLEXTEC™ 650
Pin
A
B
C
D
E
F
Wiring
77 Remote potentiometer, 5K
76 Remote potentiometer, wiper
75 Remote potentiometer, common
Trigger, common
Trigger, input
Ground
CABLE CONNECTIONS
See FIGURE A.2 for locating 6-pin and 14-pin con-
nectors on the front of the FLEXTEC™ 650.
FIGURE A.2
Function
6-pin remote
control con-
nector for
remote or
hand/foot
amptrol.
A
E
C
F
B
D
6-PIN REMOTE CONTROL CONNECTOR
Pin
A
B
C
D
E
F
G
H
I
J
K
L
M
N
Wiring
115 VAC
Ground
Trigger, Common
Trigger input
77 Remote potentiometer, 5K
76 Remote potentiometer, wiper
75 Remote potentiometer, common
Voltage Sense (21)
Motor (42 VAC)
115 VAC
Motor (42 VAC)
Function
14 pin con-
nector for
wire feeder
connectivity.
G
F
E
M
N
D
B
A
J
I
L
K
C
H
14-PIN CONNECTOR FOR WIRE FEEDER
14-PIN CONNECTOR
FOR WIRE FEEDER
6-PIN REMOTE
CONTROL CONNECTOR