Observe all Safety Guidelines detailed throughout this manual


Charger Logic

1.

the clamps are connected to the

or ba

system, the charger is plugged in to wall power,

the

default

ngs are 12V, 2A.

2.

When the ON/OFF is pressed once, charging begins as long as the

voltage is greater than 2V

(or 4V for the 24V

ng) and less than 14.8V (28.6 for the 24V se ng). If the voltages are outside the

norms, the bad

ery (and buzzer for 5 seconds) or wrong connec on light comes on.

3.

If the voltage does not reach 11 volts (or 22 volts for the 24V

ng)

2 minutes of charging, the bad

light comes on, and the buzzer sounds for 5 seconds.

4.

When the voltage reaches 14.5V (28.8 in 24V se

the charged light comes on.

5.

Two minutes later, if the voltage drops below 12V (or 24V for the 24V s

ng), the bad

ery light comes

on, and the buzzer for 5 seconds.

6.

If the ba

has not reached charged status within 24 hours, the bad

ery light comes on, and the

buzzer sounds for 5 seconds.

Note that the unit’s cooling fan comes on if the internal temperature reaches 100C, and reduces the output to
2A. When the temperature drops below 80C, the units returns to it’s original amperage se

10/6/2A 12V, 6/2A 24V High Frequency Charger

E-1

TROUBLESHOOTING