Installation, Technical specifications – autodrive, Input voltage, current – Lincoln Electric IM10069 AutoDrive 4R100 User Manual
Page 8: Physical dimensions, Gearing - wire feed speed range-wire size

DUTY CYCLE
• The duty cycle is based upon the amount of welding performed in a 10 minute period.
• Thermal test have been performed at ambient temperature. The duty cycle (duty factory) @ 40°C (104ºF) has
been determined by simulation .
A-1
INSTALLATION
A-1
AutoDrive
®
4R100
TECHNICAL SPECIFICATIONS – AutoDrive
®
4R100 (K3002-1)
TEMPERATURE RANGE
OPERATION:
-40°F to 104°F (-40°C to 40°C)
STORAGE:
-40°F to 185°F (-40°C to 85°C)
INPUT VOLTAGE, CURRENT
HEIGHT
WIDTH
LENGTH WEIGHT
8.4 Inches
7.5 Inches 9.1 Inches 13.2 lbs
(213 mm) ( 191 mm)
(231 mm) (6.0 kg)
PHYSICAL DIMENSIONS
INPUT VOLTAGE ± 10%
0-40 VDC
INPUT AMPERES
4A
RATED OUTPUT @ 104°F (40°C)
DUTY CYCLE
100% rating
INPUT AMPERES
500
GEARING - WIRE FEED SPEED RANGE-WIRE SIZE
WFS RANGE
50 – 800 ipm
(1.3 – 20.3m/min)
WFS RANGE
50 – 800 ipm
(1.3 – 20.3m/min)
WIRE SIZES
.023 – .045"
(0.6 – 1.2mm)
WIRE SIZES
.035 - .045”
(0.9 – 1.2mm)
GEARING
K3002-1
GMAW
FCAW