A-2
INSTALLATION
CIRCULATOR
A-2
TECHNICAL SPECIFICATIONS:
Model#: AD1326-8
CIRCULATOR
MAKE/MODEL
DESCRIPTION
INPUT VOLTAGE NOMINAL CURRENT
+/- 10% (MAX.)
CIRCULATOR
AIR HANDLING 380-480V/3~/50-60Hz 13.9A
INPUT
HEIGHT WIDTH
DEPTH
WEIGHT
213.6 in.
92.1 in.
53.2 in.
1764 lbs.
5425 mm
2340 mm
1350 mm
800 kg.
PHYSICAL DIMENSIONS
41
0
F (5
0
C) to 113
0
F (45
0
C) MAX.
80%
TEMPERATURE RANGE
RELATIVE HUMIDITY
Cellulose fibers provided with precoat
2 x 807 ft
2
(2 x 75 m
2
)
FILTER MATERIAL
FILTER SURFACE AREA
According to DIN EN 60335-2-69
FILTER CLASS L
Dry and Oil Free (ISO 8573-3 class 6)
85 PSI (6 Bar) MAX
COMPRESSED AIR QUALITY
REQUIRED PRESSURE
Quick Connect Coupling ø 9mm (CEJN 320)
Max: 5.3 ft
3
/min. (87 lbs./in
2
)
Depending on the degree of filter saturation
COMPRESSED AIR CONNECTION
COMPRESSED AIR CONSUMPTION
90 Minutes MAX
OFFLINE CLEANING CYCLE DURATION
F with PTC
IP54
INSULATION CLASS FAN
PROTECTION CLASS