Operation – Lincoln Electric IM10079 LN-25 PRO DUAL POWER User Manual
Page 23
POWER-UP SEQUENCE
All of the LEDʼs will briefly illuminate during power-up.
1. WIRE
FEED
SPEED/AMPERAGE
DISPLAY
Idle
The left display shows the preset wire feed speed.
The right display shows OCV. The wire feed speed
LED is lit. If the wire feeder is connected for electrode
negative welding, then the voltage display shows a
minus sign.
Welding
The value in the left display will show actual wire feed
speed or amperage as indicated by the LED below the
display. The right display shows the arc voltage. If
the wire feeder is connected for electrode negative
welding, then the voltage display shows a minus sign.
A V E R T I S S E M E N T
A
V
WFS
A V E R T I S S E M E N T
A
V
AMPS
VOLTAGE
B-5
OPERATION
B-5
LN-25™ PRO DUAL POWER
CASE FRONT CONTROLS
Figure B.3
ITEM DESCRIPTION
1
Digital Display
2
Wire Feed Speed Knob
3
5 pin gun trigger connector
4
Work sense lead
5
Set-up Pushbutton
6
Remote Voltage Control Knob
1
2
3
4
5
6