A-4
INSTALLATION
LTA 2.0-CW™
A-4
ATTACHING THE COUNTERWEIGHT
CASING
• Slide the counterweight casing (C) over the counter-
weight.
• Using a 13mm wrench, fasten the casing to the wall
mounting bracket (A) using 2 bolts M8x10 and 2 lock
washers M8 (B).
• Securely tighten bolts.
ATTACHING THE ROPE
• Pull the arm to the longest position.
• Guide the rope through the rotating hinge (D) and
over the pulley (C), the counterweight pulley (B) and
the other small pulley (A).
• Keep the counterweight in the highest position,
which means just below the small pulleys. Securely
fasten the rope to the counterweight by tying a knot
(E). The rope should be threaded through the hole
in the counterweight pulley. The knot must be large
enough so the rope cannot slip back through the
hole.
A B C
D
E
CAUTION
• Tying the counterweight too low will affect the
reach of the extraction arm.
B
C
A