Support equipment required, Technical specifications, Magnum – Lincoln Electric IM10168 K3355-,K3356-,K3357-,K3358- MAGNUM PRO AL Push Pull Gun User Manual
Page 8

A - 1
TECHNICAL SPECIFICATIONS -
Magnum
®
Pro AL Gun AC (K3356, K3355), WC (K3358, K3357)
SPECIFICATIONS
Make/Model Controller
Cable
Air or Water
Cooled
Wire Speed
AMPS
Duty Cycle
K3356 - [ ]
7-Pin
Air Cooled
800 IPM (20.3 mpm)
Max. at rated feeder Input
Voltage (42VAC)
225 Amps/25 Volts
60%
(All ratings are
using Argon Gas)
K3358 - [ ]
7-Pin
Water Cooled
450 Amps/25 Volts
K3355 - [ ]
12-Pin
Air Cooled
225 Amps/25 Volts
K3357 - [ ]
12-Pin
Water Cooled
450 Amps/25 Volts
INSTALLATION
MAGNUM
®
PRO AL Gun
WIRE CAPACITY
.030 - 1/16" (0.8mm - 1.6mm) aluminum and cored wire
SUPPORT EQUIPMENT REQUIRED
•
• Regulated gas supply and hoses.
• Properly sized power leads from power source to wire feeder and ground.
• Water source and hose capable of providing a minimum of 1 quart (.95 liter) / min.
at 45 p.s.i. when using water cooled guns.