Page 33: B-17, Display operation

Advertising
background image

B-17

OPERATION

B-17

POWER FEED™ 25M

PULSE

PULSE-ON-PULSE

FREQUENCY:

FREQ.MODULATION

(Low)-10.0 to
(High)+10.0

(Low)-10.0 to
(High)+10.0

DESCRIPTION

For Pulse -On-Pulse modes,
Arc controls changes the frequ-
ency modulation. The freque-
-ncy modulation controls the
spacing of the ripples in the
weld. Use low values for slow
travel speeds and wide welds,
and high values for fast travel
speeds and narrower welds.

For Pulse modes, Arc Control

changes the pulsing frequency.
When the frequency changes,
the Power Wave system auto-
matically adjusts the back-
ground current to maintain a
similar heat input into the weld.
Low frequencies give more con-
trol over the puddle and high
frequencies minimize spatter.

Preflow Time

Run-In WFS:

Start Procedure

DESCRIPTION

Adjusts the time that shielding

gas flows after the trigger is

pulled and prior to feeding wire.

Run-in sets the wire feed
speed from the time the trigger
is pulled until an arc is estab-
lished or 2.5 seconds.
The Start Procedure controls
the WFS. Trim at a specified
time at the beginning of the
weld. During the start time, the
machine will ramp up or down
from the Start Procedure to the
preset Welding Procedure.

EFFECT / RANGE

EFFECT / RANGE

Burnback:

Crater Procedure

FUNCTION

The burnback time is the
amount of time that the weld
output continues after the wire
stops feeding. It prevents the
wire from sticking in the puddle
and prepares the end of the
wire for the next arc start.
Crater Procedure controls the
WFS and Trim for a specified
time at the end of the weld
after the trigger is released.
During the Crater time, the
machine will ramp up or down
from the Weld Procedure to
the Crater Procedure.

ELECTRODE AND GAS

ALUMINUM 4043
ALUMINUM 4043
ALUMINUM 5356
ALUMINUM 5356

Ar
Ar
Ar
Ar

WIRE SIZE

0.035 3/64 1/16

149 72 74

98 99 100

152 76 78
101 102 103

WELD MODES

START OPTIONS

END OPTIONS

ULTIMARC*

Spot Timer

Adjust the time welding will
continue even if the trigger
is still pulled. This option
has no effect in 4-Step
Trigger Mode.

Aluminum
3/64

4043 Pulse Ar

72

START OPTIONS

END OPTIONS

SET

SETUP

WELD MODE

ARC CONTROL

*Wave Control in Power Wave

355 and 455 machines.

®

Postflow Time:

Adjusts the time that shielding
gas flows after the welding out-
put turns off.

WFS

AMPS

VOLTS

TRIM

220

1.06

Display Operation

USER INTERFACE Operation, Aluminum GMAW-P (Pulsed MIG) and GMAW-PP (Pulse on Pulse) Welding

Advertising