Operation, Caution – Lincoln Electric IM10017 RANGER 225 User Manual

Page 17

Advertising
background image

RANGE” SWITCH

The “Range” switch is used to select one of four
amperage ranges with generous overlap for Stick/TIG
welding, or one Wire Feed welding range.

Never change the “RANGE” Switch setting while
welding. This will damage the switch.

------------------------------------------------------------------------

CONTROL” DIAL

Provides a fine welding current adjustment within the
Range Switch settings in the STICK mode and weld-
ing voltage control with the Range switch set in the
wire feed mode.

Process Range Setting Current Range

B-2

OPERATION

B-2

RANGER® 225

CAUTION

KOHLER

23 H.P. COMMAND (CH23S, CH680)

.40 Gallons/Hour

(1.50 Liters/Hour)

.7 Gallons/Hour

(2.8 Liters/Hour)

1.3 Gallons/Hour

(4.9 Liters/Hour)

1.2 Gallons/Hour

(4.5 Liters/Hour)

1.4 Gallons/Hour)

(5.3 Liters/Hour)

Low Idle - No Load

2400 RPM

High Idle - No Load
3700 RPM
DC CC Weld Output
210 Amps @ 25 Volts
DC CV Weld Output
200 Amps @ 20 Volts
Auxiliary Power
9000 Watts

RANGER® 225 APPROXIMATE FUEL CONSUMPTION

STICK/TIG

(constant current)
(3 range settings)

WIRE FEED

(constant voltage)

(1 range setting)

90 Max.

145 Max.
225 MAX

15 to 25V

40 to 90 Amps

70 to 145 Amps

120 to 225 Amps

Up to 200 Amps

KOHLER

23 H.P. COMMAND (CH730)

.41 Gallons/Hour

(1.6 Liters/Hour)

.9 Gallons/Hour

(3.5 Liters/Hour)

1.5 Gallons/Hour

(5.7 Liters/Hour)

1.4 Gallons/Hour

(5.2 Liters/Hour)

1.7 Gallons/Hour

(6.4 Liters/Hour)

Advertising