INSTALLATION

POWER WAVE

®

S500

A-6

SMAW (STICK) WELDING

Similar to TIG welding a user interface is required for
adjusting the Stick welding settings. A Power Feed
wire feeder can be used as the user interface, or a
K3001-2 (user interface control panel) can be installed
into the power source (Figure A.3). The connection
diagram shown is based on the S-Series user inter-
face (K3001-2). In this diagram the remote control box
is optional.

REMOTE CONTROL BOX
K857

TO POSITIVE (+) STUD

TO REMOTE CONTROL
RECEPTACLE

TO NEGATIVE (-) STUD

ELECTRODE HOLDER KIT
K2394-1 KIT
(INICLUDES GROUND CLAMP)

WORK PIECE

WORK CLAMP

USER INTERFACE
CONTROL PANEL
K3001-2

STICK WITH S-SERIES USER INTERFACE

FIGURE A.3