Installation – Lincoln Electric IM10144 POWER WAVE S700 User Manual
Page 22

A-15
INSTALLATION
POWER WAVE
®
S700
A-15
Amperes
200
200
250
250
250
250
300
300
350
400
400
500
600
600
600
650
650
700
800
800
900
900
Percent Duty
Cycle
60
100
30
40
60
100
60
100
40
60
100
60
60
80
100
60
80
100
80
100
80
100
0 to 50 Ft.
2
2
3
2
1
1
1
2/0
1/0
2/0
3/0
2/0
3/0
2-1/0
2-1/0
3/0
2-1/0
2-2/0
3-1/0
2-3/0
2-4/0
3-3/0
50 to 100 Ft.
2
2
3
2
1
1
1
2/0
1/0
2/0
3/0
2/0
3/0
2-1/0
2-1/0
3/0
2-1/0
2-2/0
3-1/0
2-3/0
2-4/0
3-3/0
100 to 150 Ft.
2
2
2
1
1
1
1
2/0
2/0
2/0
3/0
3/0
3/0
2-1/0
2-1/0
4/0
2-1/0
2-3/0
3-1/0
2-3/0
2-4/0
3-3/0
150 to 200 Ft.
1
1
1
1
1
1
1/0
2/0
2/0
3/0
3/0
3/0
4/0
2-2/0
2-2/0
2-2/0
2-2/0
2-3/0
2-3/0
2-3/0
2-4/0
3-3/0
200 to 250 Ft.
1/0
1/0
1/0
1/0
1/0
1/0
2/0
3/0
3/0
4/0
4/0
4/0
2-3/0
2-3/0
2-3/0
2-3/0
2-3/0
2-4/0
2-4/0
2-4/0
4-2/0
3-3/0
CABLE SIZES FOR COMBINED LENGTHS OF ELECTRODE AND WORK
CABLES [RUBBER COVERED COPPER - RATED
167°F (75°C)]
**
OUTPUT CABLE GUIDELINES
(Table A.1)
** Tabled values are for operation at ambient temperatures of 104°F (40°C) and below. Applications above 104°F (40°C) may
require cables larger than recommended, or cables rated higher than 167°F (75°C).