A-1

INSTALLATION

A-1

Weight

Including

Torch Cable

40 - 40.8 lbs.

18-18.5 kg.

INPUT - SINGLE PHASE 60 HERTZ

RATED OUTPUT AT 40° C

OUTPUT

RECOMMEND INPUT WIRE AND FUSE SIZES

REQUIRED GAS FLOW RATE

REQUIRED GAS INLET PRESSURE

PHYSICAL DIMENSIONS

TECHNICAL SPECIFICATIONS -TOMAHAWK™ 375 AIR

Standard Voltage

Duty Cycle

100%

60%
35%

Current

Range

10-25 Amps

AC Input

Voltage

at

60 Hertz

230V-1Ø

208V-1Ø

Fuse

(Super Lag)

Circuit Breaker

(Delay Type)

20 AMPS

#12 (3.3 mm

2

)

2 Input Supply Wires 1 Ground Wire

#12 (3.3 mm

2

)

Type S, SO, ST, STO or extra

hard usage input cord

AWG (IEC) Sizes

Depth

18.9 in.

480 mm

Width

8.5 in.

215 mm

Height

15.2 in.

385 mm

Open Circuit

Voltage

460 VDC

For all plasma cutting applications

Based on U.S. National Electrical Code

Ambient Temperature 30

o

C or Less

Pilot Current

12 Amps

CURRENT AMPS

13 A
18 A
25 A

VOLTAGE VOLTS

85.2 VDC
87.2 VDC

90 VDC

208V, 230V ±10% / 1 / 60Hz

70 PSI @ 125-200 SCFH

( 5 Bar. @ 80±20 LITERS/MIN.)

80 to 110 PSI

(6 Bar. to 7.5 Bar.)

25 A

Output

Input Cord Plug Size

6-50P

TOMAHAWK™ 375 AIR

TEMPERATURE RANGES

OPERATING TEMPERATURE RANGE

-10°C to +40°C

STORAGE TEMPERATURE RANGE

-10°C to +40°C