Operation, Machine interface, B-11 – Lincoln Electric IM10026 TOMAHAWK 1000 User Manual

Page 21: Arc start, Arc initiated, Arc voltage

Advertising
background image

B-11

OPERATION

B-11

MACHINE INTERFACE

The TOMAHAWK™ 1000 comes standard with a
machine interface. Interface signals provided include:
arc start, arc initiated, and arc voltage. These signals
are accessible through the 14 pin connector on the
case front.

ARC START:

The Arc Start circuit allows for triggering of the power
source to commence cutting. This circuit can be
accessed through pins K and M of the 14 pin connec-
tor. The circuit has a 15 VDC nominal open circuit
voltage and requires a dry contact closure to activate.

ARC INITIATED:

The Arc Initiated circuit provides information as to
when a cutting arc has transferred to the work piece.
This circuit can be accessed through pins I and J of
the 14 pin connector. The circuit provides a dry con-
tact closure when the arc has transferred. Input to this
circuit should be limited to 0.3 A for either 120VAC or
30VDC.

ARC VOLTAGE:

The Arc Voltage circuit can be used for activating a
torch height control. This circuit can be accessed
through pins D and G of the 14 pin connector. The
circuit provides full electrode to work arc voltage (no
voltage divider, 270VDC maximum).

Users wishing to utilize the Machine Interface can
order a K867 Universal Adapter (please adhere to the
pin locations stated above) or manufacture a 14 pin
connector cable assembly.

TOMAHAWK™ 1000

1 4 - P I N B O X R E C E P T A C L E , F R O N T V I E W

J

I

H

N

G

F

E

D

C

L

A r c S t a r t

A r c V o l t a g e

A r c I n i t i a t e d

M

K

Advertising