Lincoln Electric IM10161 X-TRACTOR 8A User Manual

Page 13

Advertising
background image

MAINTENANCE

X-TRACTOR

®

8A WELDING FUME EXTRACTOR

RETURNING THE TIMER TO THE FACTORY SETTINGS
Factory settings of each timer: 3sec. ON time, 30min. OFF time,
function ‘A’. No matter how you change the settings you can always
reset all settings to factory settings following these easy steps:

1. Disconnect the unit from the power supply.

2. Press and hold down (off/arrow down) and (TEST) buttons.

3. Connect the unit to the power supply.

4. Release the buttons after 'P' appears on the display.

5. Then 'A' appears on the display - do not press anything.

6. After a few seconds the unit will resume operation with factory

settings.

7. Change the presset ON and/or OFF times if required

OFF-LINE FILTER CLEANING

When the X-TRACTOR 8A is off, the signal to the solenoid valve is
controlled by an additional timer placed inside the cabinet. This timer
keeps the signal on for a certain period of time in order to run two or
three more cleaning cycles after the extraction unit is shut down
(OFF-line cleaning). Inside the filter container, there is a cover that
closes the inlet in order to avoid dust being blown out in the
duct/hose system.

FIGURE 4

The timer is pre-set at the factory to the values in the following table.

Normally it is not necessary to adjust the timer.

13

OFF-LINE CLEANING SPECIFICATIONS

FUNCTION

MULTI-FUNCTION

MOUNTING

DIN-RAIL MOUNTING

DIMENSION

.67” (DIN 43880)

RANGE

0.1 S X - 100 H

SUPPLY

24 - 240 VAC & 24 VDC

CONNECTION

SCREW TERMINAL

I/O SIGNAL

8 A SPDT RELAY

TYPE

SYM. RECYCLER, INTERVAL,

DELAY ON OP./REL.

I/O FUNCTION

7 FUNCTIONS

SETTING OF TIME

SETTING OF TIME RANGE

SETTING OF FUNCTION

TIMER VALUES

FUNCTION

DELAYED OUT

TIME RANGE

60 SEC.

TIME

3 (TOTAL IS 3 X 60 SEC = 3 MIN.)

TIMER SPECIFICATIONS

INTERVAL (OFF) TIME

.01 SEC. - 99 HR.

(note: check response time of your sole-

noid valve)

DISCHARGE (ON) TIME

.01 SEC. - 99 HR.

(note: check response time of your sole-

noid valve)

SUPPLY VOLTAGE

110 – 240V AC/DC 50-60HZ (± 10%)

48 – 115V AC/DC 50-60HZ (± 10%)

10-48 V AC/DC 50-60HZ (± 10%)

CURRENT CONSUMPTION

MAX. 7mA

OPERATING TEMPERATURE

-40ºF TO +140ºF (-40ºC TO +60ºC)

ENVIRONMENTAL PROTECTION

IP65 WHEN INSTALLED

CASE MATERIAL

ABS PLASTIC FR GRADE

CONNECTION

DIN 43650A - ISO 4400

INDICATOR

DIGITAL DISPLAY

TIMER CERTIFICATIONS

CE

YES

cULus

YES

RoHS

YES

IP65

YES

Advertising