Operation, Warning, Opera t or’s manual – Lincoln Electric IMT10049 WIRE FEEDER WELDER 125, 140 User Manual

Page 17: B. install shielding gas, Shielding gas

Advertising
background image

B-8

OPERATION

B-8

WIRE FEEDER WELDERS (125, 140 MODELS)

B. INSTALL SHIELDING GAS

MIG welding requires an appropriate bottle of shielding
gas. For mild steel a cylinder of Ar/CO

2

or 100% CO

2

can be used; refer to the following instructions to prop-
erly connect shielding gas to the machine.

CYLINDER may explode if dam-
aged. Keep cylinder upright and
chained to support

• Keep cylinder away from areas

where it may be damaged.

• Never lift welder with cylinder

attached.

• Never allow welding electrode to

touch cylinder.

• Keep cylinder away from welding

or other live electrical circuits.

WARNING

75/25

FEMALE END

MALE END

CO

S19298

REGULATOR

ADAPTER

PLASTIC

WASHER

MIXES

100%

2

3. Attach the flow regulator to the cylinder valve and

tighten the union nut securely with a wrench.

NOTE: If connecting to 100% CO

2

cylinder, a CO

2

regulator adapter is required. Purchase separately
S19298 CO

2

adapter, be sure to install plastic washer

included in the fitting on the bottle side.(See Figure
B.13 )

4. Refer to Figure B.13. Attach one end of inlet gas

hose to the outlet fitting of the flow regulator and tight-
en the union nut securely with a wrench. Connect the
other end to the machine Solenoid Inlet Fitting (5/8-18
female threads — for CGA — 032 fitting). Make cer-
tain the gas hose is not kinked or twisted.

FIGURE B.13

BUILDUP OF SHIELDING GAS may
harm health or kill.

• Shut off shielding gas supply

when not in use.

1. Secure the cylinder to a wall or other stationary

support to prevent the cylinder from falling
over. Insulate the cylinder from the work circuit
and earth ground. Refer to Figure B.13.

2. With the cylinder securely installed, remove the

cylinder cap. Stand to one side away from the
outlet and open the cylinder valve very slightly
for an instant. This blows away any dust or dirt
which may have accumulated in the valve out-
let.

BE SURE TO KEEP YOUR FACE AWAY FROM
THE VALVE OUTLET WHEN “CRACKING” THE
VALVE. Never stand directly in front of or behind
the flow regulator when opening the cylinder
valve. Always stand to one side.

WARNING

WARNING

SHIELDING GAS

1. For CO

2

, open the cylinder very slowly. For argon-

mixed gas, open cylinder valve slowly a fraction of a
turn. When the cylinder pressure gauge pointer stops
moving, open the valve fully.

2. Set gas flow rate for 30 to 40 cubic feet per hour (14

to 18 L/min) under normal conditions. Increase to as
high as 40 to 50 CFH (18 to 23.5 L/min) for out of
position welding.

3. Keep the cylinder valve closed, except when using

the machine.

OPERA

T

OR’S MANUAL