Pumptec 114T SERIES User Manual

Page 8

Advertising
background image

8

Version 012313

Pumptec Operating Instructions and Parts Manual

PUMP SERIES 114T

9. Place manifold on top of plunger and head assembly. It may

be necessary to move heads on plunger to have valves align

with valve pockets on manifold. be careful to not lose the

o-rings or valves in the manifold during re-assembly. You may

hear a click when everything is aligned.

10. Place nut in to hex cavity behind head while inserting

shorter bolts and washer assembly into manifold. Tighten to

close gap between manifold and head, but DO nOT tighten

completely at this time.

Figure 7

11.

Install black grease from included packet into corners and

center of plunger slot as shown.

Figure 8

11.

Mount pump back onto motor and tighten mounting bolts

to 14 in/lbs of torque. Tighten head bolts to 14 in/lbs of torque.

LuBriCAtiON

Apply 1.5 oz of suppliers black grease to the corners and center

of plunger slot at the time of service.

StorINg

For extended storing, or between use in cold climates, drain all

pumped liquids from pump and flush with antifreeze solution

to prevent freezing and damage to the pump. DO nOT RUn

PUMP WITH FROZEn lIQUID.

Note:

Each system’s maintenance cycle will be unique. If

system performance decreases, check immediately. If no wear

at 500 hours, check again at 1000 hours and each 500 hours

until wear is observed. Valves typically require changing every

seal change. Duty cycle, temperature, quality of pumped liquid

and inlet feed conditions all effect the life of a pump’s wear

parts and service cycle.

Note:

Remember to service the regulator/uploader at each

seal servicing and check all system accessories and connections

before resuming operation.

PrEVENtiVE MAiNtENANCE CHECkLiSt

Check

daily weekly 50

Hrs.

500

Hrs.

1500

Hrs.

3000

Hrs.

Clean Filters

X

Water leaks

X

Descale Pump

X

X

Cam & bearing

X

X

Seal Change

X

X

Valve Change

X

X

Advertising