Trouble shooting guide, Conditions possible cause correction, Capstan will not pull maximum load – Ramsey Winch 16K Capstan User Manual
Page 6: Slow line speed, Excessive noise
Advertising

CONDITIONS
POSSIBLE CAUSE
CORRECTION
CAPSTAN WILL NOT
PULL MAXIMUM
LOAD
1. System relief valve may be set too
low
2. Low Hydraulic Oil
1.
Increase relief valve setting until
recommended pressure is obtained.
2. Check/Fill oil in reservoir
SLOW LINE SPEED
1. Relief valve may be clogged
2. Low Hydraulic Oil
3. Low Hydraulic System Flow rate.
4. Motor worn out
1. Remove/Clean relief valve.
Re-Install valve and reset pressure
2. Check/Fill
reservoir
3. Check flow rate. Refer to Page 3
Hydraulic system requirements.
4. Replace motor
EXCESSIVE NOISE
1. Hydraulic system flow too high
1. Check flow rate. Refer to Page 3
Hydraulic system requirements.
TROUBLE SHOOTING GUIDE
4