Typical layout, Flow, gpm – Ramsey Winch RPH-15000 (CURRENT) User Manual
Page 6

HYDRAULIC SYSTEM REQUIREMENTS
Refer to the performance charts below to properly match your hydraulic system to the winch performance. The
charts consist of: (1) line pull (LB) first layer vs. working pressure (PSI); (2) line speed, first layer (FPM) vs. flow
(GPM). A motor spool directional control valve is recommended.
* Caution: Do not exceed 20 G.P.M. If exceeded, motor and winch may be damaged.
PERFORMANCE CHARTS
SYSTEM REQUIREMENTS:
2500 PSI RELIEF VALVE SETTING
15 G.P.M. FLOW RATE *
10 MICRON NORMAL FILTRATION
6
HIGH PRESSURE LINE
(.50 I.D. MINIMUM)
CONTROL VALVE
3 POSITION
4 WAY VALVE
(MOTOR SPOOL)
DUAL-A & B PORT CONTROL
WITH BRAKE RELEASE SHUTTLE
BRAKE
PORT
B
MOTOR
A
TYPICAL LAYOUT
LOW PRESSURE LINE
(.75 I.D. MINIMUM)
MAX. FLOW &
PRESSURE AT
RATED LOAD:
15 GPM
2500 PSI
PUMP
PERFORMANCE WITH 24.0 CU. IN. HYDRAULIC MOTOR:
LINE PULL
, L
B
S
FIRST LAYER
FIRST LAYER
LINE SPEED, FPM
WORKING PRESSURE, PSI
AT 15 GPM
500
0
0
2500
2000
1000
1500
3000
6000
FLOW, GPM
0
0
15
5
10
5
10
15000
9000
12000
25
15
20